			 Speed Controller SPD-24500R Installation and Wiring  | 
		
			  | 
		
| Rated Voltage | 24 Volts | 
| Rated For Motors | Up To 500 Watts | 
| Maximum Current | 30 Amps | 
| Rated For Chargers | Up To 3 Amps | 
| Conversion Efficiency | 95% | 
| Under Voltage Protection | 20.5 Volts | 
| Recommended Fuse Size | 40 Amps | 
| Dimensions | 4-3/8" L x 2-5/8" W x 1-5/8" H | 
| Under Voltage Battery Protection: 
			When the battery pack falls below a specific Voltage the controller 
			turns the motor off preventing over discharging of the battery pack 
			which extends the battery packs lifespan. (The cutoff value is 
			approximately 20.5 Volts ± 1.0 Volts) Motor Cut-Off During Braking: When the brakes are engaged the brake switch signals the controller to turn off the motor.  | 
		
| 
			 
            *Power Connector  | 
			
			 
			  | 
		
| Motor 
			Connector Blue = Positive White = Negative Mating Connector Item # CNX-50  | 
			
			
			![]() Required Connection  | 
		
| Throttle 
			Connector Mating Connector Item # CNX-52  | 
			
			
			![]() Required Connection  | 
		
| Key 
			and Forward/Reverse Switch Connector  Mating Connector Item # CNX-52  | 
			
			
			![]() Connect Red+Yellow wires for power on in forward. Connect Red+Yellow+Blue wires for power on in reverse. Required Connection  | 
		
| 
			Battery Charger Connector Mating Connector Item # CNX-51  | 
			
			
			![]() ~Optional Connection  | 
		
| Brake 
			Lever 
			Switch Connector Mating Connector Item # CNX-51  | 
			
			
			![]() ~Optional Connection  | 
		
| Brake 
			Light Connector Mating Connector Item # CNX-51  | 
			
			![]() ~Optional Connection  | 
		
| Power 
			Light Connector Mating Connector Item # CNX-51  | 
			
			![]() ~Optional Connection  | 
		
| 
			*The power connector 
			should be the last connection made.  *Fuse or circuit breaker protection is required between speed controller and battery pack. ~Optional Connections do not need to be hooked up for the speed controller to operate.  |